To avoid confusion while formatting a DASD device change the level of
the "Expected VOL1 label not found" message from warning to info.
Signed-off-by: Stefan Haberland <[email protected]>
Signed-off-by: Martin Schwidefsky <[email protected]>
From: Ben Hutchings <[email protected]>
Extended VBLKs (those larger than the preset VBLK size) are divided
into fragments, each with its own VBLK header. Our LDM implementation
generally assumes that each VBLK is contiguous in memory, so these
fragments must be assembled before further processing.
Currently the reassembly seems to be done quite wrongly - no VBLK
header is copied into the contiguous buffer, and the length of the
header is subtracted twice from each fragment. Also the total
length of the reassembled VBLK is calculated incorrectly.
Signed-off-by: Ben Hutchings <[email protected]>
Signed-off-by: Anton Altaparmakov <[email protected]>