VCCR is used as a trigger to start voltage transitions, so
we need to mark it volatile in order to make sure it gets
written to hardware every time we set a new voltage.
Fixes regulator voltage being stuck at the first voltage
set after driver load.
[lst: reworded commit message]
Signed-off-by: Steffen Trumtrar <[email protected]>
Signed-off-by: Lucas Stach <[email protected]>
Signed-off-by: Mark Brown <[email protected]>
Cc: [email protected]
'ltc3589_reg_defaults' is local to this file. Make it static.
Signed-off-by: Sachin Kamat <[email protected]>
Signed-off-by: Mark Brown <[email protected]>
of_find_node_by_name() walks the allnodes list, and can thus walk
outside of the parent node. Use of_get_child_by_name() instead.
Signed-off-by: Axel Lin <[email protected]>
Signed-off-by: Mark Brown <[email protected]>
When fixed_uV is set and n_voltage is 1, regulator core will return
rdev->desc->fixed_uV in regulator_get_voltage() and regulator_list_voltage().
Rename ltc3589_standby_regulator_ops to ltc3589_fixed_standby_regulator_ops,
this makes the code clear that the ops is for fixed voltage regulator.
Signed-off-by: Axel Lin <[email protected]>
Acked-by: Philipp Zabel <[email protected]>
Signed-off-by: Mark Brown <[email protected]>
This patch adds support for the Linear Technology LTC3589, LTC3589-1,
and LTC3589-2 8-output I2C voltage regulator ICs.
Signed-off-by: Lucas Stach <[email protected]>
Signed-off-by: Philipp Zabel <[email protected]>
Signed-off-by: Mark Brown <[email protected]>