Commit Graph
4 Commits
Author SHA1 Message Date
Punit Agrawal 208cd822a1 thermal: trace: Trace when temperature is above a trip point
Create a new event to trace when the temperature is above a trip
point. Use the trace-point when handling non-critical and critical
trip pionts.

Cc: Zhang Rui <[email protected]>
Cc: Eduardo Valentin <[email protected]>
Cc: Steven Rostedt <[email protected]>
Cc: Frederic Weisbecker <[email protected]>
Cc: Ingo Molnar <[email protected]>
Signed-off-by: Punit Agrawal <[email protected]>
Signed-off-by: Eduardo Valentin <[email protected]>
2014-07-29 09:28:43 -04:00
Zhang Rui 80a26a5c22 Thermal: build thermal governors into thermal_sys module
The thermal governors are part of the thermal framework,
rather than a seperate feature/module.
Because the generic thermal layer can not work without
thermal governors, and it must load the thermal governors
during its initialization.

Build them into one module in this patch.

This also fix a problem that the generic thermal layer does not
work when CONFIG_THERMAL=m and CONFIG_THERMAL_GOV_XXX=y.

Signed-off-by: Zhang Rui <[email protected]>
Acked-by: Eduardo Valentin <[email protected]>
Acked-by: Durgadoss R <[email protected]>
2013-04-14 23:28:43 +08:00
Sachin Kamat 621769334b thermal: fair_share: Add missing static storage class specifiers
Fixes the following sparse warnings:
drivers/thermal/fair_share.c:80:5: warning:
symbol 'fair_share_throttle' was not declared. Should it be static?
drivers/thermal/fair_share.c:111:25: warning:
symbol 'thermal_gov_fair_share' was not declared. Should it be static?

Signed-off-by: Sachin Kamat <[email protected]>
Acked-by: Durgadoss R <[email protected]>
Signed-off-by: Zhang Rui <[email protected]>
2012-11-05 14:00:10 +08:00
Durgadoss R 4ccc5743ae Thermal: Introduce fair_share thermal governor
This patch introduces a simple 'weight' based
governor named fair_share governor. Whenever the
thermal framework gets notified of the trip point
violation, this governor (if configured), throttles
the cooling devices associated with a thermal zone.

This mapping between a thermal zone and a cooling device
and the effectiveness of cooling are provided in the
platform layer.

Signed-off-by: Durgadoss R <[email protected]>
Signed-off-by: Zhang Rui <[email protected]>
2012-11-05 14:00:07 +08:00