All amba drivers return 0 in their remove callback. Together with the
driver core ignoring the return value anyhow, it doesn't make sense to
return a value here.
Change the remove prototype to return void, which makes it explicit that
returning an error value doesn't work as expected. This simplifies changing
the core remove callback to return void, too.
Reviewed-by: Ulf Hansson <[email protected]>
Reviewed-by: Arnd Bergmann <[email protected]>
Acked-by: Alexandre Belloni <[email protected]>
Acked-by: Dmitry Torokhov <[email protected]>
Acked-by: Krzysztof Kozlowski <[email protected]> # for drivers/memory
Acked-by: Mark Brown <[email protected]>
Acked-by: Linus Walleij <[email protected]>
Acked-by: Suzuki K Poulose <[email protected]> # for hwtracing/coresight
Acked-By: Vinod Koul <[email protected]> # for dmaengine
Acked-by: Guenter Roeck <[email protected]> # for watchdog
Acked-by: Wolfram Sang <[email protected]> # for I2C
Acked-by: Takashi Iwai <[email protected]> # for sound
Acked-by: Vladimir Zapolskiy <[email protected]> # for memory/pl172
Acked-by: Greg Kroah-Hartman <[email protected]>
Link: https://lore.kernel.org/r/[email protected]
Signed-off-by: Uwe Kleine-König <[email protected]>
The change adds support of ARM PrimeCell PL176 MPMC.
Static memory configuration of PL175 MPMC is very similar to one found
on PL172 and PL175 controllers, so it is preferred to add its support
into the existing driver. The difference is that PL176 supports up to
10 slave ports (but only 4 of them may be connected to static memory
devices), AHB master bus width cab be 64-bit wide, also NAND devices
can be interfaced.
Similar to PL175 contoller, PL176 has no write buffer enable control
in static memory configuration register, the rest of static memory
configuration bits (with exception of NAND) is the same.
Signed-off-by: Vladimir Zapolskiy <[email protected]>
Signed-off-by: Joachim Eastwood <[email protected]>
The change adds support of ARM PrimeCell PL175 MPMC, the controller is
found on NXP LPC32xx SoC.
PL175 MPMC is very similar to PL172 controller, so it is preferred to
add its support into the existing driver.
One of the differences between PL172 and PL175 is that the latter one
supports up to 6 AHB ports, but still only 4 AHB ports can be assigned
to a static memory device, also PL175 does not have write buffer
enable control in static memory configuration register.
Signed-off-by: Vladimir Zapolskiy <[email protected]>
Signed-off-by: Joachim Eastwood <[email protected]>
According to PL172 TRM read of bits [7:6] of MPMCPeriphID3 is
undefined, so unmask them. Also the driver supports all currently
present revisions of PL172, this allows to alleviate requirements to
the revision version matched by the driver.
Signed-off-by: Vladimir Zapolskiy <[email protected]>
Signed-off-by: Joachim Eastwood <[email protected]>
Building pl172 as a module fails with:
> ERROR: "of_default_bus_match_table" [drivers/memory/pl172.ko] undefined!
Because the symbol of_default_bus_match_table isn't exported by the OF
core code so can't be referenced from modules. Fix this by removing
the usage of of_default_bus_match_table for now. The side effect of
this is that child nodes can't use "simple-bus" or "simple-mfd".
Reported-by: Mark Brown <[email protected]>
Signed-off-by: Joachim Eastwood <[email protected]>
Signed-off-by: Olof Johansson <[email protected]>
This driver makes it possible to configure the static memory
chip selects on the ARM PL172 MultiPort Memory Controller
from a set of properties in DT. Configuration of dynamic
memory is not supported and is left to the boot loader.
The intended usage is to setup timing and configuration for
static memory devices like NAND and NOR Flash before they
are probed by a driver.
Signed-off-by: Joachim Eastwood <[email protected]>
Signed-off-by: Olof Johansson <[email protected]>