Zac Lanzon 743b4481b6 hwmon: (asus_rog_ryujin) Fix pump control source on the Ryujin III
The RYUJIN III pump has a 4-pin cable for a motherboard fan header in
addition to USB. Byte 2 of the set cooler duty command selects the pump
control source: 0 hands the pump to its internal controller, which
follows the PWM of the header its 4-pin cable is plugged into, and 1
makes it follow the pump duty in byte 3. Byte 3 of the cooler duty
report returns the current source.

The driver fills byte 2 with duty_channel, which is 1 for the RYUJIN
III, and a pwm2 write re-sends the reported pump duty with the new fan
duty. So writing only the internal fan duty takes the pump away from
its internal controller.

Measured on a RYUJIN III 360 (firmware AURJ2-S750-0108) with the pump
cable on AIO_PUMP and the header PWM set through nct6775, after loading
the driver with the pump on its internal controller (pump rpm):

                                   header 50%   header 80%   source
  no write yet                        2160         3090         0
  pwm2 = 40%, before this patch       1740         1740         1
  pwm2 = 40%, with this patch         2130         3090         0

Send the reported source with pwm2 writes. The fan duty applies with
either source (40%: 1545 to 1590 rpm, 30%: 870 rpm). A pwm2 write sent
right after a pwm1 write that took the pump over, before the report
could show the change, left the pump on USB and applied its fan duty
(2 of 2 trials, and 7 of 7 with raw commands up to 0.9 s after).

pwm1 writes keep selecting source 1. The cooler reports the pump duty of
the last write, whichever source it selected, and 40% after power-on.
Byte 9 of the status report follows the duty the pump runs at. Measured
from power-on (PSU switched off) once per driver, with the header at
100%:

                                  before this patch   with this patch
                                  source duty  rpm    source duty  rpm
  no write yet                       0    100  3570      0    100  3570
  pwm2 = 40%                         1    100  3570      0    100  3570
  pwm1 = 40%, the reported duty      1    100  3570      1     40  1710
  pwm1 = 60%                         1     60  2430
  pwm1 = 40%                         1     40  1725

So a pwm1 write of the reported duty did not reach the pump, while
other duties applied in one write, also when taking the pump from its
internal controller (60%: 2460 rpm). When a pwm1 write requests the
reported duty, write a duty 1% away first (below at 100%), then the
requested one. Sent back to back, the two writes left the pump at the
requested duty in all 19 trials, 9 with raw commands and 10 through
this driver.

Tested on the RYUJIN III 360 only. The EXTREME, EVA and WHITE EDITION
use the same rog_ryujin_iii_info and send the same command, and Edward
Blair's analysis of the WHITE EDITION firmware shows the same pump
control source. The RYUJIN II, whose duty_channel is 0, is unchanged.

Fixes: cd258aca0d ("hwmon: (asus_rog_ryujin) Add ROG Ryujin III support")
Closes: https://github.com/aleksamagicka/asus_rog_ryujin-hwmon/issues/12
Suggested-by: Edward Blair <[email protected]>
Cc: [email protected]
Signed-off-by: Zac Lanzon <[email protected]>
Link: https://patch.msgid.link/7ca8fe6cd6b4125813613bd4187ff6cdda72e4b6.1790512964.git.lanzonza@gmail.com
[groeck: Dropped obsolete 'Assisted-by: tag]
Signed-off-by: Guenter Roeck <[email protected]>
2026-11-02 07:00:04 -08:00
..
2026-08-10 08:59:40 -07:00
2025-11-02 11:07:16 -08:00
2026-10-18 09:35:06 -07:00
2026-08-10 08:59:42 -07:00
2024-08-27 08:10:23 -07:00
2019-11-06 14:37:19 -08:00
2023-10-29 22:22:20 -07:00
2024-01-02 08:44:55 -08:00
2026-04-11 00:02:13 -07:00
2024-06-28 10:27:47 -07:00
2025-10-12 14:14:22 -07:00
2026-05-24 13:54:01 -07:00
2024-06-12 08:59:44 -07:00
2024-07-02 12:36:31 -07:00
2026-01-31 07:38:31 -08:00
2024-06-12 22:39:34 -07:00
2025-09-08 06:13:16 -07:00
2023-10-27 07:27:23 -07:00
2021-08-17 14:54:25 -07:00