It appears about all functions in arch/x86/lib/atomic64_cx8_32.S are wrong in case cmpxchg8b must be restarted, because LOCK_PREFIX macro defines a label "1" clashing with other local labels : 1: some_instructions LOCK_PREFIX cmpxchg8b (%ebp) jne 1b / jumps to beginning of LOCK_PREFIX ! A possible fix is to use a magic label "672" in LOCK_PREFIX asm definition, similar to the "671" one we defined in LOCK_PREFIX_HERE. Signed-off-by: Eric Dumazet <[email protected]> Acked-by: Jan Beulich <[email protected]> Cc: Christoph Lameter <[email protected]> Cc: Linus Torvalds <[email protected]> Cc: Andrew Morton <[email protected]> Link: http://lkml.kernel.org/r/1325608540.2320.103.camel@edumazet-HP-Compaq-6005-Pro-SFF-PC Signed-off-by: Ingo Molnar <[email protected]>
27 lines
382 B
C
27 lines
382 B
C
#ifdef __ASSEMBLY__
|
|
|
|
#include <asm/asm.h>
|
|
|
|
#ifdef CONFIG_SMP
|
|
.macro LOCK_PREFIX
|
|
672: lock
|
|
.section .smp_locks,"a"
|
|
.balign 4
|
|
.long 672b - .
|
|
.previous
|
|
.endm
|
|
#else
|
|
.macro LOCK_PREFIX
|
|
.endm
|
|
#endif
|
|
|
|
.macro altinstruction_entry orig alt feature orig_len alt_len
|
|
.long \orig - .
|
|
.long \alt - .
|
|
.word \feature
|
|
.byte \orig_len
|
|
.byte \alt_len
|
|
.endm
|
|
|
|
#endif /* __ASSEMBLY__ */
|