mirror of
https://github.com/torvalds/linux.git
synced 2026-11-25 07:52:34 +00:00
[Why] Nominal pixel clock and EDID information differ in precision so although monitor reports maximum refresh is 2x minimum, LFC was not being enabled. [How] Use minimum refresh rate as nominal/2 when EDID dictates that min refresh = max refresh/2. v2: squash in 64 bit divide fix Signed-off-by: Aric Cyr <[email protected]> Reviewed-by: Nicholas Kazlauskas <[email protected]> Acked-by: Rodrigo Siqueira <[email protected]> Signed-off-by: Alex Deucher <[email protected]>