mirror of
https://github.com/torvalds/linux.git
synced 2026-11-25 07:52:34 +00:00
Default voltage constraints were being provided for fixed voltage regulator where board constraints were not provided but these constraints used INT_MIN as the default minimum voltage which is not a valid value since it is less than zero. Use 1uV instead. Also set the default values we set in the constraints themselves since otherwise the max_uV constraint we determine will not be stored in the actual constraint strucutre and will therefore not be used. Signed-off-by: Mark Brown <[email protected]> Signed-off-by: Liam Girdwood <[email protected]>