pSeries machines on POWER9 processors can run with the XICS (legacy)
interrupt mode or with the XIVE exploitation interrupt mode. These
interrupt contollers have different interfaces for interrupt
management : XICS uses hcalls and XIVE loads and stores on a page.
H_EOI being a XICS interface the enable_scrq_irq() routine can fail
when the machine runs in XIVE mode.
Fix that by calling the EOI handler of the interrupt chip.
Fixes: f23e0643cd ("ibmvnic: Clear pending interrupt after device reset")
Signed-off-by: Cédric Le Goater <[email protected]>
Signed-off-by: David S. Miller <[email protected]>